Cone-Beam Computed Tomography Dataset of a Walnut Imaged at 4 Different Dose Levels

Summary This dataset is a collection of X-ray projection images of a walnut imaged in a cone-beam computed tomography (CBCT) scanner, using four different dose levels. The dataset also includes a metadata file for each of the scans, specifying the scan geometry and other i

👤
CreatorAlexander, Meaney
📅
Published2024-05-31
🔗
DOI10.5281/zenodo.11397266
📊
Downloads1,504
⚖️
Licensecc-by-4.0
File Size7.0 GB
Data TypeDataset
Published2024
Licensecc-by-4.0
Total Views1,526
Total Downloads1,504

Summary

This dataset is a collection of X-ray projection images of a walnut imaged in a cone-beam computed tomography (CBCT) scanner, using four different dose levels. The dataset also includes a metadata file for each of the scans, specifying the scan geometry and other important scan parameters.

 

Description

Sample Information

The sample is a walnut in its shell. For the scanning process double-sided tape was used to attach the sample to a plastic tube placed into the rotation stage.

Scanner

The measurements were acquired using a cone-beam computed tomography scanner designed and constructed in-house in the Industrial Mathematics Computed Tomography Laboratory at the University of Helsinki. The scanner consists of a molybdenum target X-ray tube (Oxford Instruments XTF5011), a motorized rotation stage (Thorlabs CR1-Z7), and a 12-bit, 2240×2368 pixel, energy-integrating flat panel detector (Hamatsu Photonics C7942CA-22).

Scan Settings

The dataset consists of four different scans of the same sample. For each scan 360 X-ray projections were acquired using an angle increment of 1 degrees, with one additional frame taken at the end to estimate sample movement. The X-ray source was set at 40 kV with a 0.5 mm aluminum filter. For the different scans, the relative doses, tube currents, and exposure times were:

  • 100 % relative dose: tube current 1 mA, exposure time 2000 ms,
  • 50 % relative dose: tube current 1 mA, exposure time 1000 ms,
  • 25 % relative dose: tube current 0.5 mA, exposure time 1000 ms,
  • 10 % relative dose: tube current 0.2 mA, exposure time 1000 ms.

Data Post-Processing

Before the scans, two correction images were acquired for each scan setting. A dark current image was created by averaging 255 images taken with the X-ray source off. A flat-field image was created by averaging 255 images taken with the X-ray source switched on with no sample placed in the scanner. After the scan, dark current and flat-field corrections were applied to each projection image using the Hamamatsu HiPic imaging software version 9.3.

Data Format

The X-ray projections are stored in .tif format. The metadata are contained in .txt files with formatting that is both human-readable and machine-readable.

Notes

Due to a slightly misaligned center of rotation in the scanner, the CT reconstructions can appear blurry. It was empirically observed that this problem can be compensated for quite well by shifting each projection left by 4 pixels, using circular boundary conditions, before performing any other operations on the projections. It was also observed that the scans are not entirely aligned, with a small angular discrepancy between each reconstruction.

 

Research Group

This dataset was

📤 Share this page

Found this useful? Share it with your network.

✓ Link copied! Paste it on ResearchGate / Academia.edu
📦
Cone-Beam Computed Tomography Dataset of a Walnut Imaged… (Full Dataset)7.0 GB
⬇
📄
ReadmeVia DOI record
↗

Files are hosted on the source repository. Click download to access the full dataset.

Alexander, Meaney (2024). Cone-Beam Computed Tomography Dataset of a Walnut Imaged at 4 Different Dose Levels. https://doi.org/10.5281/zenodo.11397266