Skip to content
JournalsWorldThe Global Research Discovery Platform
Featured Dataset

Data set

Monitoring exercise intensity is essential for optimizing the health benefits of physical activity. Indirect calorimetry is the gold-standard method for assessing metabolic stress during exercise, though, its reliance on extensive equipment for sampling and analyzing exhaled gases restricts its w

👤
CreatorYajima, Katsuhiko
📅
Published2026-05-14
🔗
DOI10.5281/zenodo.20176685
📊
Downloads19
⚖️
Licensecc-by-4.0
Data TypeDataset
Published2026
Licensecc-by-4.0
Total Views80
Total Downloads19

Monitoring exercise intensity is essential for optimizing the health benefits of physical activity. Indirect calorimetry is the gold-standard method for assessing metabolic stress during exercise, though, its reliance on extensive equipment for sampling and analyzing exhaled gases restricts its widespread application. Skin interstitial fluid may represent an ideal biofluid for the continuous monitoring of whole-body metabolism and exercise intensity. However, specific metabolites in skin interstitial fluid that are more closely associated with metabolic variables measured by indirect calorimetry remain unknown. We examined which metabolites in skin interstitial fluid most closely reflect metabolic responses assessed by indirect calorimetry during a continuous graded exercise protocol. Twelve young participants (5 females) exercised at low, moderate, and high-intensity phases (25%, 50%, and 75% VO₂peak), each lasting 20 min. Metabolites in skin dialysate, which reflect the composition of skin interstitial fluid, were collected via intradermal microdialysis during each exercise and analyzed. Medium- and long-chain acylcarnitines in skin dialysate increased during moderate-intensity exercise in line with elevations in whole-body fat oxidation. During high-intensity phase, lactic acid in skin dialysate was elevated along with increases in whole-body carbohydrate oxidation. Many metabolites including those mentioned above in skin dialysate were correlated with whole-body metabolic responses. Our preliminary data suggest that metabolite concentrations in skin interstitial fluid may be associated with variables measured by indirect calorimetry. These findings may inform the future development of wearable devices that could potentially be used for continuous and noninvasive monitoring of exercise intensity.

📤 Share this page

Found this useful? Share it with your network.

✓ Link copied! Paste it on ResearchGate / Academia.edu
📦
Data set (Full Dataset)Size varies
⬇
📄
ReadmeVia DOI record
↗

Files are hosted on the source repository. Click download to access the full dataset.

Yajima, Katsuhiko (2026). Data set. https://doi.org/10.5281/zenodo.20176685