Skip to content
JournalsWorldThe Global Research Discovery Platform
Featured Dataset

EDEN2020 Human Brain MRI Datasets for Healthy Volunteers

High-resolution  MR datasets of a cohort of 15 healthy adult subjects acquired on  a  3T  scanner  at  the Neuroradiology Unit and CERMAC (Center  of Excellence for High Field Magnetic Resonance), Vita-Salute San Raffaele University and IRCCS San Raffaele Scient

👤
CreatorCastellano, Antonella
📅
Published2019-07-16
🔗
DOI10.5281/zenodo.3994749
📊
Downloads4,935
⚖️
Licensecc-by-nc-nd-4.0
File Size6.4 GB
Data TypeDataset
Published2019
Licensecc-by-nc-nd-4.0
Total Views4,053
Total Downloads4,935

High-resolution  MR datasets of a cohort of 15 healthy adult subjects acquired on  a  3T  scanner  at  the Neuroradiology Unit and CERMAC (Center  of Excellence for High Field Magnetic Resonance), Vita-Salute San Raffaele University and IRCCS San Raffaele Scientific Institute, Milano, Italy. The data includes:

  • T1_3D_PROSET_Sag:  T1-weighted  volumetric  sequence  acquired  on  the sagittal plane for  morphological  characterization.  This  sequence  demonstrates  difference  in  the  T1 relaxation time of tissues and provide excellent contrast between GM and WM.
  • 3D_FLAIR_Tra: Fluid‑Attenuated Inversion Recovery volumetric sequence acquired on the axial planefor morphological characterization. This is an inversion recovery sequence with a long inversion time (TI), which results in removing signal from the cerebrospinal fluid from the images.
  • SWIp_axial: Susceptibility‑Weighted Imaging sequence acquired on the axial plane.This  is  a three-dimensional  high-spatial  resolution  Gradient  Echo  MRI  sequence providing excellent contrast for venous vascular modeling.
  • s3DI_MC_HR: three‑dimensional   high‑resolution   time‑of‑flight   (TOF)   MR angiography  acquisition  to visualize  flow  within  the  arterial  vessel.  It  is  based  on  the phenomenon of flow-related enhancement of spins entering into an imaging slice. As a result of being unsaturated, these spins give more signal that surrounding stationary spins.
  • MIP_s3DI_MC_HR:  angiographic  3D  visualization  of  TOF  images  using  the maximum intensity projection (MIP) technique of reconstruction.
  • raw_data_DTI_32: Diffusion Tensor Imaging raw data. This is a diffusion-weighted Spin  Echo  EPI  single-shot  pulse  sequence  acquired  on  the axial  planealong  32  gradient directions at a b-value of 1000 s/mm2 and one volume without diffusion-weighting (b0 image).
  • raw_data_NODDI: multi-compartmental dMRI sequence for advanced tractography and  NODDI  analyses,  including  an  axial  high  angular  resolution  diffusion-weighted  imaging (HARDI) acquisition along 60 gradient directions at a b-value of 3000 s/mm2,a DTI acquisition along 35 directions at a b-value of 711 s/mm2 and 11 volumes without diffusion-weighting  (b0  images).  The  phase-encoding  direction was  anterior-to-posterior for all these acquisitions.
  • B0_reverse: a sequence without diffusion-weighting having the same geometrical parameters of the ‘raw_data_NODDI’ images, but acqui

    📤 Share this page

    Found this useful? Share it with your network.

    ✓ Link copied! Paste it on ResearchGate / Academia.edu
📦
EDEN2020 Human Brain MRI Datasets for Healthy Volunteers (Full Dataset)6.4 GB
⬇
📄
ReadmeVia DOI record
↗

Files are hosted on the source repository. Click download to access the full dataset.

Castellano, Antonella (2019). EDEN2020 Human Brain MRI Datasets for Healthy Volunteers. https://doi.org/10.5281/zenodo.3994749