Skip to content
JournalsWorldThe Global Research Discovery Platform
Featured Dataset

OPM brain spinal cord data (1/2)

This dataset contains concurrent brain and spinal cord recordings made with optically pumped magnetometers (OPMs), together with surface electromyography (EMG), acquired during rest and sustained voluntary hand contraction (abductor pollicis brevis, APB). Due to file size, data from 7 participant

👤
CreatorSpedden, Meaghan Elizabeth
📅
Published2026-06-24
🔗
DOI10.5281/zenodo.20824565
📊
Downloads273
⚖️
Licensecc-by-4.0
File Size43.4 GB
Data TypeDataset
Published2026
Licensecc-by-4.0
Total Views143
Total Downloads273

This dataset contains concurrent brain and spinal cord recordings made with optically pumped magnetometers (OPMs), together with surface electromyography (EMG), acquired during rest and sustained voluntary hand contraction (abductor pollicis brevis, APB). Due to file size, data from 7 participants is available in this repository. Data from the remaining 2 participants is available at 10.5281/zenodo.20824827.

Code for preprocessing data and analysing brain–spinal cord–muscle functional connectivity is available at https://github.com/meaghanspedden/brainspine-connectivity. Meshes, lead fields, and MNI-to-native transformation matrix required for source reconstruction and figure generation are provided in the Leadfields meshes/ folder of this repository. Pre-computed results files for regenerating the main paper figures without re-running the full pipeline are available in the forGeneratingFigures/ folder at 10.5281/zenodo.20824827.

Experimental task

Participants lay supine in a magnetically shielded room (MSR) wearing a custom 3D-printed scanner-cast. They performed alternating two-minute blocks of weak sustained right thumb abduction (~15% of maximal voluntary contraction) and rest, for five cycles.

OPM recordings

Brain and spinal cord magnetic fields were recorded simultaneously using 64 triaxial QuSpin Neuro-1 third-generation OPM sensors (QuSpin Inc., Louisville, CO, USA), mounted in a custom scanner-cast covering the scalp, neck, chest, and back. The system has an intrinsic bandwidth of 0–135 Hz. Experiments were conducted in a 438 × 338 × 218 cm MSR (Magnetic Shields Ltd, UK). Data were acquired at 1500 Hz.

EMG recordings

Surface EMG was recorded from the right APB muscle at 1000 Hz using pairs of surface electrodes (Ambu Ltd, Denmark), with a reference electrode at the right wrist. Signals were amplified and digitised outside the MSR using a BrainAmp system (Brain Products, Germany) and synchronised to OPM data via TTL pulse.

Forward models and source reconstruction

Spinal cord magnetic field forward modelling was performed using a Biot-Savart law approximation. Each source point was modelled as a current dipole oriented along three orthogonal axes along the centre line of the spinal cord, with the magnetic field at each sensor computed analytically from the sensor-source geometry. 

Notes

Participant OP00212 has anatomical co-registration, the remaining participants use the common reference anatomy.

 

/
├── Leadfields_meshes/
│   ├── geometries_experimental_withbrain.mat  # Spinal cord geometry for Biot Savart forward model
│   ├── leadfield_experimental_bslaw_experimental.mat  # Precomputed Biot Savart lead field
│   └── T.mat           &nbsp

📤 Share this page

Found this useful? Share it with your network.

✓ Link copied! Paste it on ResearchGate / Academia.edu
📦
OPM brain spinal cord data (1/2) (Full Dataset)43.4 GB
⬇
📄
ReadmeVia DOI record
↗

Files are hosted on the source repository. Click download to access the full dataset.

Spedden, Meaghan Elizabeth (2026). OPM brain spinal cord data (1/2). https://doi.org/10.5281/zenodo.20824565