STEMPO – dynamic X-ray tomography phantom

The Spatio-TEmporal Motor-Powered (STEMPO) phantom is a physical phantom designed for collecting dynamic X-ray tomography data. The dynamic part of the phantom is computer controlled allowing for wide variety of different measurements and sampling setups to be used. The primary g

👤
CreatorHeikkilä, Tommi
📅
Published2023-08-11
🔗
DOI10.5281/zenodo.8239013
📊
Downloads12,409
⚖️
Licensecc-by-4.0
File Size1.7 GB
Data TypeDataset
Published2023
Licensecc-by-4.0
Total Views1,934
Total Downloads12,409

The Spatio-TEmporal Motor-Powered (STEMPO) phantom is a physical phantom designed for collecting dynamic X-ray tomography data. The dynamic part of the phantom is computer controlled allowing for wide variety of different measurements and sampling setups to be used. The primary goal is to help mathematical community test and validate novel dynamic tomography reconstruction methods.

Detailed documentation of the phantom, the included data (volume 1 only) and some examples can be found on the related publication: https://doi.org/10.1007/978-981-97-6769-4_1 (available as an arXiv preprint: http://arxiv.org/abs/2209.12471).

This data set can be appended with new data in the future. Current version (1.2) includes
         Data – vol.1 (v1.0)

  • stempo_static_2d_b*.mat
  • stempo_static_3d_b*.mat
  • stempo_cont360_2d_b*.mat
  • stempo_cont360_3d_b*.mat
  • stempo_seq8x45_2d_b*.mat
  • stempo_seq8x45_3d_b*.mat
  • stempo_data_geometries.csv

         Data – vol.2 (added in v1.2)

  • stempo_seq8x180_2d_b*.mat
  • stempo_seq8x180_3d_b*.mat

where b* denotes downsampling or binning of the data by a factor of (4, 8, 16 or 32). These are 2D and 3D data collected from a static object for reference, or from a dynamic target in a continuous 360 projection scan or sequence of 8 rotations, each consisting of 45 or 180 projections (with seq8x45 and seq8x180 data respectively). Finally stempo_data_geometries.csv is a simple table containing the key parameters of the measurement geometry in text format. Note that the height of the phantom for volume 2 data is slightly different compared to volume 1, including the static scan (mostly relevant for comparing 3D reconstructions).

In addition the data set contains

         Additional files

  • stempo_ground_truth_2d_b4.mat

which is an approximation of the true motion obtained from a single static FBP reconstruction which has been interpolated to match the location of the moving block during the cont360 and seq8x45 scans. Finally there are

         Example algorithms

  • stempo_fbp_example.m
  • stempo_fdk_example.m
  • stempo_pdfp_wavelet_2d_example.m
  • stempo_LplusS_2d_example.m

which are short example algorithms of well know analytic (FBP and FDK) and iterative methods. stempo_pdfp_wavelet_2d.m uses variational regularization and wavelet transform of th

📤 Share this page

Found this useful? Share it with your network.

✓ Link copied! Paste it on ResearchGate / Academia.edu
📦
STEMPO – dynamic X-ray tomography phantom (Full Dataset)1.7 GB
⬇
📄
ReadmeVia DOI record
↗

Files are hosted on the source repository. Click download to access the full dataset.

Heikkilä, Tommi (2023). STEMPO – dynamic X-ray tomography phantom. https://doi.org/10.5281/zenodo.8239013