Academic Journal
Quartile not availableJournal of Chromatography & Separation Techniques
About Journal of Chromatography & Separation Techniques
Journal of Chromatography & Separation Techniques — A Full Profile
The Journal of Chromatography & Separation Techniques is an open-access, peer-reviewed scientific journal devoted to separation science: the family of laboratory methods used to pull complex mixtures apart into their individual components so that each component can be identified, measured or collected in purified form. Its recorded ISSN is 2157-7064, and articles in the journal carry digital object identifiers built on the 10.4172 prefix, for example 10.4172/2157-7064.1000360. The journal's own pages present it as an international title aimed at analytical scientists working in pharmaceutical, environmental, food and clinical laboratories, and its article archive shows a steady flow of method-development and method-application papers through the 2010s, reaching volume 8 in 2017. This profile explains what the journal publishes, how its editorial process is described by its publisher, what authors are told about charges, how the title has moved between publishing imprints, and — equally important — which commonly repeated claims about the journal could not be verified from official sources and should therefore be treated with caution.
Identity at a Glance
- Full title: Journal of Chromatography & Separation Techniques
- Common abbreviation: J Chromatogr Sep Tech
- ISSN: 2157-7064 (the only ISSN shown on the publisher's journal pages; no separate print ISSN is displayed)
- NLM catalog identifier: 101623510, as stated on the publisher's journal page
- DOI prefix seen on published articles: 10.4172
- Field: analytical chemistry, with separation science as the core subject
- Access model: open access, financed by author-side handling charges rather than subscriptions, according to the publisher's instructions for authors
- Peer review model stated by the publisher: double-blind review
- Publisher history: long associated with OMICS International (OMICS Publishing Group); the journal's current instructions-for-authors page states that the journal is organised by Longdom Publishing SL — readers should note the change of imprint discussed below
- Language: English
Two identity points matter for anyone citing or submitting to this journal. First, the title is easily confused with older, unrelated chromatography titles. It is not Journal of Chromatography A (an Elsevier title), it is not the Journal of Chromatographic Science (an Oxford University Press title), and it is not the Japanese society journal Chromatography. The ISSN 2157-7064 is the safest single check that a record, an article PDF or a citation really belongs to this journal. Second, the journal's branding has appeared under more than one publishing house name over its life, so the imprint printed on an individual article PDF — OMICS-era articles carry OMICS International branding — may differ from the imprint named on the journal's current web pages. That is a normal thing to check, and this profile flags it openly rather than silently choosing one name.
What Separation Science Is, and Why a Journal Is Devoted to It
Almost every quantitative measurement in chemistry begins with a separation problem. A blood sample, a river-water sample, a tablet powder and a plant extract are all mixtures containing hundreds or thousands of compounds, most of them irrelevant to the question being asked and many of them capable of distorting the measurement of the one compound that matters. Separation science is the discipline that solves that problem. Its classical tool is chromatography, in which a mixture is carried by a moving phase — a liquid in liquid chromatography, a gas in gas chromatography — through a stationary phase that holds different compounds back by different amounts, so that the compounds leave the system at different times and can be detected one by one. Around that core sit a wider family of techniques: electrophoresis, which separates charged species in an electric field; extraction, filtration, distillation, evaporation, centrifugation, crystallisation, precipitation and adsorption, which separate by solubility, size, volatility, density or surface behaviour; and sample-preparation methods that clean a crude sample up before the main separation begins.
The journal exists because these methods are not settled technology. Columns, stationary phases, detectors and software all keep changing; sample types keep getting harder, from monoclonal antibody products with subtle charge variants to pesticide residues at trace levels in fatty foods; and regulators keep tightening the validation standards that an analytical method must meet before its results can support a drug approval, a food-safety decision or an environmental prosecution. A specialist journal gives method developers a place to publish incremental but genuinely useful advances — a faster gradient, a more robust extraction, a cheaper column chemistry — that a general chemistry journal might consider too applied, while giving practising analysts a searchable record of methods that have already been shown to work on real samples.
Aims and Scope in Detail
The publisher's scope statement for the journal is deliberately broad, and it is worth unpacking because it defines what an author can reasonably submit. The named core is chromatography in its many forms: analytical chromatography, thin-layer chromatography, high-performance liquid chromatography, gas chromatography, supercritical fluid chromatography and gel permeation chromatography all appear in the journal's own descriptions of its territory, alongside the wider separation techniques listed above — electrophoresis, filtration, distillation, evaporation, centrifugation, precipitation and related physical methods. Mass spectrometry is treated as part of the scope in its own right, reflecting how often modern separations are coupled directly to a mass spectrometer so that separated compounds are identified as well as quantified. The scope also extends to spectroscopic methods, micro-analytical techniques, electro-migration techniques, thermogravimetric analysis, chiral separations — the separation of mirror-image molecules, a persistent problem in pharmaceutical analysis because mirror-image forms of a drug can behave very differently in the body — and nano-fluidic and micro-fluidic separations.
Beyond technique, the scope is defined by application. The publisher lists the qualitative and quantitative analysis of biopolymers, including monoclonal antibodies, proteins, peptides and their post-translational modifications, nucleic acids and glycans; comparative profiling of biological systems using lipidomics, metabolomics, genomics, proteomics and other large-scale measurement approaches; clinical analysis, toxicological analysis, doping analysis and therapeutic drug monitoring; veterinary applications; the analysis of environmental contaminants in biological systems; the screening and profiling of cells, tissues, body fluids and other biological matrices; the measurement of endogenous compounds and biomarkers; and the identification of new bioactive compounds. Preparative work is explicitly welcome too: the journal states that it accepts work on preparative separations used to isolate and purify components of biological systems, including affinity separations. In practice, the published archive matches this scope statement. Typical articles develop and validate a chromatographic assay for a named drug in plasma or in a food matrix, apply high-performance thin-layer chromatography to fingerprint a medicinal plant, use two-dimensional liquid chromatography to characterise degradation products of a therapeutic antibody, or review a class of separation approaches such as continuous chromatographic reprocessing. A manuscript that merely uses a routine, unmodified commercial assay with no methodological point to make sits at the edge of the stated scope; the publisher says reports of analytical methods for compounds in early pharmaceutical development are considered when the authors can demonstrate the broader significance of the methodology, and that quality-control analyses of bulk drugs, natural products and pharmaceutical formulations are also considered.
Article Types and the Shape of a Typical Paper
The journal publishes research articles and critical reviews, and its archive also contains editorials and editor's notes that survey the contents of an issue. A typical research article follows the validation-driven structure that analytical chemistry expects: an introduction explaining the analyte and why measuring it is difficult; a materials and methods section giving the instrument, column, mobile phase, extraction procedure and calibration design in enough detail to be repeated; a results section reporting linearity, detection and quantification limits, precision, accuracy and recovery; stability experiments where the matrix demands them — freeze–thaw cycles, bench-top stability and post-preparative stability are recurring features in the journal's bioanalytical papers; and a discussion placing the new method against earlier published methods. Review articles survey a technique or application area. Shorter editorial items frame special content. Authors should note that the journal's archive is dominated by full method papers rather than by short communications, and that the strongest fit is a paper whose contribution is the method itself — its selectivity, sensitivity, robustness or speed — rather than a biological finding that happens to have been produced with a chromatographic instrument.
Publisher, Imprints and an Honest Note on the Record
For most of its visible history this journal was an OMICS International title. Article PDFs from the 2010s carry OMICS branding, the journal was listed in OMICS journal directories, and an OMICS article-processing-charge schedule from that period listed the journal, under the shortened name Chromatography & Separation Techniques, at a charge of 900 in the schedule's currency column. The directory record for this post on Journals World likewise names OMICS Publishing Group as publisher, reflecting that era. However, the journal's current web presence sits with Longdom, and Longdom's instructions-for-authors page for the journal states that the journal is organised by Longdom Publishing SL, a self-supporting organisation that receives no funding from any institution or government. Longdom's journal page reproduces the scope statement, gives the NLM identifier and describes the review and fast-track arrangements quoted in this profile. Because the two imprints appear in different layers of the record, this profile reports both: OMICS is the publisher of record for the historical archive, and Longdom is the organiser named on the current journal pages. Anyone who needs the legally current publisher — for a library licence, a copyright query or a research-integrity complaint — should take the name from the journal's live instructions page at the time they act, not from an older article PDF or from a third-party directory, including this one.
A second honest note concerns reputation. OMICS, the journal's historical publisher, was the subject of sustained public controversy during the 2010s about the quality of peer review and the marketing practices of large open-access publishers, and OMICS titles were frequently discussed in that debate. This profile does not repeat allegations as facts: what can be verified from the journal's own pages is the process the publisher describes, and what can be verified from the archive is the content the journal actually published, which includes methodologically ordinary, carefully validated analytical papers alongside shorter and lighter items. The practical advice is the same advice that applies to any open-access title: read recent issues yourself, check whether the specific articles you would cite are methodologically sound, confirm the journal's current indexing claims on the databases' own sites, and check your institution's and funder's policies before submitting.
Peer Review and Editorial Process as Described by the Publisher
Longdom's peer-review page for the journal states that the journal follows a double-blind peer-review system, in which reviewers do not know the identity of the authors and authors do not know the identity of the reviewers. The main journal page states that all submitted manuscripts are subjected to a peer-review process and are evaluated on originality and clarity of exposition, and the instructions page adds that acceptance is driven by the handling editorial team together with independent peer review. The instructions also give an average article processing time of 55 days. Alongside the regular route, the journal participates in a paid Fast Editorial Execution and Review Process: for an additional prepayment of 99 US dollars on top of the regular article processing charge, the publisher promises a faster pre-review response (a maximum of three days), a reviewer process of a maximum of five days, and revision or publication within two days, with a further five days for external review if the handling editor requests revision. The fee is stated to be non-refundable even if the article is rejected or withdrawn. Authors should weigh that offer carefully: a faster timetable is a service, not a quality signal, and no legitimate editorial outcome should ever be understood as guaranteed by a payment. The existence of the fast track is reported here because it is part of the journal's official offer, and because transparent knowledge of it helps authors compare this journal honestly with slower, subscription-based analytical chemistry titles.
Access, Charges and Licensing Facts
The journal is open access: articles are freely readable online, and the publisher explains the model on the basis that, because there are no subscription payments, authors pay a handling fee after acceptance. The instructions state that there are no submission charges, that payment is required only after a manuscript has been accepted, and that the article processing charge is negotiable or can be waived by decision of the editorial board for authors from low-income countries or where the research is not funded. No single current charge figure is stated in the text of the current instructions page consulted for this profile, so this profile does not quote a current figure as fact. A historical OMICS charge schedule listed the journal at 900, but that schedule is years old, belongs to the previous imprint, and should not be relied on as the present price; authors need the figure quoted to them in writing during their own submission. Licensing terms for individual articles should likewise be checked on the article itself, since open-access licences vary across publishers and across years. What can be said safely is the structure of the model: reader access is free, the costs are carried on the author side after acceptance, waivers are described as possible but discretionary, and the optional fast-track service costs extra and is non-refundable.
Indexing and Identifiers — What Is Claimed and What to Check
The publisher's journal page gives an NLM identifier (101623510), which ties the title to the US National Library of Medicine's cataloguing system, and it quotes an Index Copernicus Value for 2016 of 84.45 — a journal-level score from that service for that year, not a current metric. OMICS-era pages for the journal described indexing at services including PubMed (partial), Scopus, EBSCO, Index Copernicus and Google Scholar. Directory and aggregator claims of that kind age badly: databases add and remove titles, and a claim printed by a publisher in one year is not evidence of coverage in another. This profile therefore makes no claim that the journal is currently covered by Scopus or by any particular citation database. The correct verification route is to search the database's own source list for ISSN 2157-7064 at the time you need the answer. What is stable and verifiable is the identifier layer: the ISSN, the NLM identifier, the 10.4172 DOI prefix visible across the archive, and the journal's h-index of 22 recorded in the Journals World directory data drawn from OpenAlex — a modest, plausible figure for a niche methods journal, and a reminder that this is a specialist title whose papers are cited mainly inside the analytical-methods community rather than a general chemistry flagship.
Who Reads It, Who Publishes in It, and When It Is a Good Fit
The readership the publisher describes is analytical scientists worldwide, and the archive bears that out: authors are typically pharmaceutical analysts, food-safety and environmental laboratory scientists, natural-products researchers and bioanalytical specialists, many of them writing from institutional and industry laboratories rather than from large research universities. The journal is a plausible fit for a complete, well-validated method paper — a new assay for a drug, a residue, a biomarker or a natural product — especially where the novelty is practical: a greener solvent system, a cheaper extraction, a method that survives a difficult matrix, or a separation that resolves compounds earlier methods could not. It is a weaker fit for work whose main claim is biological or clinical, for methods with incomplete validation, and for authors whose institution requires publication in a journal currently listed in a specific citation index, since that status must be verified independently and at submission time. Authors should also keep copies of all correspondence and the exact charge quoted to them, as they should with any author-pays journal.
Frequently Asked Questions
What is the ISSN of the Journal of Chromatography & Separation Techniques? 2157-7064. It is the ISSN printed on the journal's articles and on its publisher pages, and it is the key to distinguishing this journal from similarly named chromatography titles.
Is the journal open access? Yes. The publisher describes it as an open-access journal in which articles are freely accessible online and costs are met by author-side handling charges paid after acceptance, with waivers described as possible for authors from low-income countries or with unfunded research.
Is it peer-reviewed? The publisher states that manuscripts undergo peer review, and its peer-review page specifies a double-blind system. An optional paid fast-track service is also offered; its timetable promises should be read as a publisher service offer.
Who publishes it? The historical archive is OMICS International material, and the Journals World record names OMICS Publishing Group. The journal's current instructions page states that it is organised by Longdom Publishing SL. This profile reports both, because the record itself contains both.
Does it have an impact factor? No Journal Impact Factor from Clarivate's Journal Citation Reports could be verified from official sources consulted for this profile, and the only journal-level score the publisher itself quotes is a dated Index Copernicus Value for 2016. Treat any website quoting a current impact factor for this journal as unverified until you have seen it in Journal Citation Reports itself.
Bottom Line
The Journal of Chromatography & Separation Techniques is a specialist open-access outlet for separation science: broad in technique, applied in character, and built around the validated method paper. Its identity is anchored by ISSN 2157-7064 and the 10.4172 DOI prefix; its stated process is double-blind review with author-side charges after acceptance; and its history crosses two imprints, OMICS and Longdom, which readers and authors should be aware of when they interpret older PDFs and directory entries. Verify current indexing and current charges directly at the time you need them, read the recent archive before submitting, and this journal can be judged on what it actually is rather than on the reputation of any publishing group it has belonged to.
Journal Metrics
A quartile may vary by subject category. Values without a source or reporting year are unverified historical entries. Verify the current Journal Impact Factor with Clarivate or the publisher before using it.
Aims & Scope
The publisher’s official aims and scope have not yet been verified for this profile. Use the journal website to check subject fit and accepted article types before submitting.
Recent Research Articles
Latest publications matched automatically by ISSN.
Optimization of Headspace Solid-Phase Microextraction and Gas Chromatography Coupled with Mass Spectrometry Technique for the Quantification of Volatile Compounds in a Fresh Cheese (Oaxaca)
Jose Rogelio Sandoval- Copado, Juan Orozco- Villafuerte, Maria Magdalena Garcia- Fabila, Maria de los Angeles Colin- Cruz et al.
2018 · DOI: 10.4172/2157-7064.1000415Fatty Acid Composition of Muscles Tissues of Longdong Goat (Black and White Cashmere)
Babour AJ, Wei JM, Luoa YZ
2018 · DOI: 10.4172/2157-7064.1000402LC-MS analysis of intact amino acids on a novel mixed-mode HPLC column
Itaru Yazawa
2018 · DOI: 10.4172/2157-7064-c1-041Detection of Synthetic Anti-Obesity Drugs, Designer Analogues and Weight- Loss Ingredients as Adulterants in Slimming Foods from 2015 to 2017
Yun J, Choi J, Jo C H, Kwon K et al.
2018 · DOI: 10.4172/2157-7064.1000396Forensic crime detection based on separation techniques: Recent problems and new insight to investigation
Rakhi Khanna
2018 · DOI: 10.4172/2157-7064-c3-046Comments on Uranium Content in Groundwater by Laser Fluorimetry: Method Validation and Dose Assessment
Rathore DPS
2018 · DOI: 10.4172/2157-7064.1000413QuEChERS: The Dispersive Methodology Approach for Complex Matrices
Maggira M, Samanidou V
2018 · DOI: 10.4172/2157-7064.1000398Evaluation of an Ion Chromatography Method for Quantitating Sulfate in Plasma, Serum and Urine
Paul A Dawson, Avis McWhinney, Matthew Reimer, Francis G Bowling et al.
2018 · DOI: 10.4172/2157-7064.1000411Optimization of Subcritical Water Mediated Extraction of Apple Pomace Polyphenolics and their Antioxidant Activity
Salis Ibrahim, Regina Santos, Steve Bowra
2018 · DOI: 10.4172/2157-7064.1000410Interfacial impedimetric biosensor
Terry Chilcott
2018 · DOI: 10.4172/2157-7064-c3-045Development of Analytical Method for Separation and Quantification of Cysteine Hydrochloride Monohydrate, Followed by Validation with Total Error Concept by Using Ultra Performance Liquid Chromatography with Pre-Column Derivatization
Aasodi RR, Murugan V, Kumari P, Shree V et al.
2018 · DOI: 10.4172/2157-7064.1000406Solvent extraction kinetics of silver with methyl ketonic p-tert-octylcalix[4]arene in the modified lewis cell
Jee Young Kim
2018 · DOI: 10.4172/2157-7064-c3-047Enantio Separation of HMB (1-Hydroxy Methylthio Butanoic Acid) through Chymotrypsin Catalysed Peptide Synthesis and Chiral LC-MS Assessment
Srinivasan S, Kapila S, Forciniti D, Nam P et al.
2018 · DOI: 10.4172/2157-7064.1000400New Developed UHPLC Method for Selected Urine Metabolites
Valko Rokytovska M, Ocenas P, Salayova A, Kostecka Z et al.
2018 · DOI: 10.4172/2157-7064.1000404Determination of Olanzapine in Five Different Pharmaceutical Formulations by LC-MS Method
Mevlut A, Yucel K, Mehmet Emrah Y, Onur S et al.
2018 · DOI: 10.4172/2157-7064.1000409Development of COL3A1-Specific Real-Time PCR Assay for Clinical and Sport Detection Applications
Martinez B, Jimenez A, Diaz T, Segura J et al.
2018 · DOI: 10.4172/2157-7064.1000403Development and Validation of an Innovative and Ecological Analytical Method Using High Performance Liquid Chromatography for Quantification of Cephalothin Sodium in Pharmaceutical Dosage
Aleixa do Nascimento P, Kogawa AC, Salgado HRN
2018 · DOI: 10.4172/2157-7064.1000394Graphene-Based Materials Used in as Stationary Phase for Chromatography: A Mini Review
Yang L, Guo Xiao T, Yang J, Xu Z et al.
2018 · DOI: 10.4172/2157-7064.1000399Multiplexed synchrotron photoionization mass spectrometry: Characterization of combustion and atmospheric reactions
Giovanni Meloni
2018 · DOI: 10.4172/2157-7064-c1-040Method Validation and Application of Liquid Chromatography- Mass Spectrometry/Mass Spectrometry for Determination of Neonicotinoid Pesticide Residues in Tomato
Suganthi A, Bhuvaneswari K
2018 · DOI: 10.4172/2157-7064.1000401Reviews
Community Reviews
Version History
October 17, 2026 at 5:35 am
October 10, 2026